{"id":605,"date":"2026-02-26T18:22:47","date_gmt":"2026-02-26T18:22:47","guid":{"rendered":"https:\/\/sterilecomstg.wpenginepowered.com\/?post_type=news&#038;p=605"},"modified":"2026-07-01T22:53:41","modified_gmt":"2026-07-01T22:53:41","slug":"in-situ-verification-of-disinfection-rotation-for-contamination-control","status":"publish","type":"news","link":"https:\/\/sterile.com\/pt\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/","title":{"rendered":"Verifica\u00e7\u00e3o in situ da Rota\u00e7\u00e3o de Desinfe\u00e7\u00e3o para Controlo de Contamina\u00e7\u00e3o"},"content":{"rendered":"<h1>Para ler este artigo, aceda a PDA Journal of Pharmaceutical Science Technology clicando <a href=\"https:\/\/journal.pda.org\/content\/early\/2026\/05\/29\/pdajpst.2025-000057.1\">esta liga\u00e7\u00e3o<\/a>.<\/h1>\n<h2>Resumo<\/h2>\n<p id=\"p-1\">Objetivo: As empresas de fabrica\u00e7\u00e3o de medicamentos utilizam diferentes produtos desinfetantes para salas de limpeza h\u00e1 muitos anos. No entanto, as raz\u00f5es para esta rotatividade nem sempre s\u00e3o claras e, se a quest\u00e3o for colocada a v\u00e1rios cientistas diferentes, espera-se que sejam apresentadas raz\u00f5es variadas para a rotatividade. Entende-se que os reguladores tamb\u00e9m esperam ver a rotatividade de desinfetantes, mas a regulamenta\u00e7\u00e3o escrita que fornece orienta\u00e7\u00f5es a esse respeito \u00e9 considerada bastante vaga. O Anexo 1 da GMP da Uni\u00e3o Europeia (UE) atualizado (\u2018Fabrica\u00e7\u00e3o de Medicamentos Esterilizados\u2019) faz refer\u00eancia espec\u00edfica \u00e0 rotatividade de um espiricida como parte do regime. No entanto, ainda n\u00e3o h\u00e1 orienta\u00e7\u00e3o sobre quantas ou quais formula\u00e7\u00f5es devem ser rotacionadas e a frequ\u00eancia da rotatividade a implementar.<\/p>\n<p id=\"p-2\">M\u00e9todos e Resultados: Esta avalia\u00e7\u00e3o dos resultados de testes de monitoramento ambiental in situ em quatro locais de fabrica\u00e7\u00e3o aborda a quest\u00e3o de saber se a rota\u00e7\u00e3o de mais de um desinfetante de amplo espectro \u00e9 mais eficaz do que o uso de apenas um dentro de um regime de desinfec\u00e7\u00e3o.<\/p>\n<p id=\"p-3\">Conclus\u00e3o: Neste estudo, que incluiu quatro locais de fabrica\u00e7\u00e3o, demonstrou-se que o uso de um desinfetante de amplo espectro e um esporicida era mais eficaz do que a rota\u00e7\u00e3o de dois desinfetantes de amplo espectro e um esporicida.<\/p>\n<p id=\"p-4\">Import\u00e2ncia e impacto: Esta avalia\u00e7\u00e3o fornece dados que demonstram que a rota\u00e7\u00e3o de dois desinfectantes de amplo espectro e um esporicida, em vez de um desinfectante de amplo espectro e um esporicida, n\u00e3o proporciona necessariamente qualquer benef\u00edcio em rela\u00e7\u00e3o ao controle ambiental. Isso tem implica\u00e7\u00f5es mais amplas no que diz respeito a desafiar o paradigma de que a rota\u00e7\u00e3o de mais de um desinfetante de amplo espectro em um ambiente de sala limpa \u00e9 prefer\u00edvel ou ben\u00e9fica.<\/p>","protected":false},"featured_media":28427,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"class_list":["post-605","news","type-news","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>In-situ Verification of Disinfection Rotation for Contamination Control - Veltek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sterile.com\/pt\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"In-situ Verification of Disinfection Rotation for Contamination Control - Veltek\" \/>\n<meta property=\"og:description\" content=\"To read this article, head to PDA Journal of Pharmaceutical Science Technology by clicking this link. Abstract Aim: Pharmaceutical manufacturing companies have rotated different cleanroom disinfectants for many years. However, the reasons for this rotation have not always been clear and if the question is posed to several different scientists, it is expected that varying [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sterile.com\/pt\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/\" \/>\n<meta property=\"og:site_name\" content=\"Veltek\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-01T22:53:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/sterile.com\/wp-content\/uploads\/2026\/01\/PDA-JPST.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"752\" \/>\n\t<meta property=\"og:image:height\" content=\"265\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/sterile.com\\\/news\\\/in-situ-verification-of-disinfection-rotation-for-contamination-control\\\/\",\"url\":\"https:\\\/\\\/sterile.com\\\/news\\\/in-situ-verification-of-disinfection-rotation-for-contamination-control\\\/\",\"name\":\"In-situ Verification of Disinfection Rotation for Contamination Control - Veltek\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/sterile.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/sterile.com\\\/news\\\/in-situ-verification-of-disinfection-rotation-for-contamination-control\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/sterile.com\\\/news\\\/in-situ-verification-of-disinfection-rotation-for-contamination-control\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/sterile.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/PDA-JPST.jpg\",\"datePublished\":\"2026-02-26T18:22:47+00:00\",\"dateModified\":\"2026-07-01T22:53:41+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/sterile.com\\\/news\\\/in-situ-verification-of-disinfection-rotation-for-contamination-control\\\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/sterile.com\\\/news\\\/in-situ-verification-of-disinfection-rotation-for-contamination-control\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/sterile.com\\\/news\\\/in-situ-verification-of-disinfection-rotation-for-contamination-control\\\/#primaryimage\",\"url\":\"https:\\\/\\\/sterile.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/PDA-JPST.jpg\",\"contentUrl\":\"https:\\\/\\\/sterile.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/PDA-JPST.jpg\",\"width\":752,\"height\":265},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/sterile.com\\\/news\\\/in-situ-verification-of-disinfection-rotation-for-contamination-control\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/sterile.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"In-situ Verification of Disinfection Rotation for Contamination Control\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/sterile.com\\\/#website\",\"url\":\"https:\\\/\\\/sterile.com\\\/\",\"name\":\"Veltek\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/sterile.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Verifica\u00e7\u00e3o in-situ da rota\u00e7\u00e3o de desinfec\u00e7\u00e3o para controle de contamina\u00e7\u00e3o - Veltek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sterile.com\/pt\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/","og_locale":"pt_PT","og_type":"article","og_title":"In-situ Verification of Disinfection Rotation for Contamination Control - Veltek","og_description":"To read this article, head to PDA Journal of Pharmaceutical Science Technology by clicking this link. Abstract Aim: Pharmaceutical manufacturing companies have rotated different cleanroom disinfectants for many years. However, the reasons for this rotation have not always been clear and if the question is posed to several different scientists, it is expected that varying [&hellip;]","og_url":"https:\/\/sterile.com\/pt\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/","og_site_name":"Veltek","article_modified_time":"2026-07-01T22:53:41+00:00","og_image":[{"width":752,"height":265,"url":"https:\/\/sterile.com\/wp-content\/uploads\/2026\/01\/PDA-JPST.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo estimado de leitura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/sterile.com\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/","url":"https:\/\/sterile.com\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/","name":"Verifica\u00e7\u00e3o in-situ da rota\u00e7\u00e3o de desinfec\u00e7\u00e3o para controle de contamina\u00e7\u00e3o - Veltek","isPartOf":{"@id":"https:\/\/sterile.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/sterile.com\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/#primaryimage"},"image":{"@id":"https:\/\/sterile.com\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/#primaryimage"},"thumbnailUrl":"https:\/\/sterile.com\/wp-content\/uploads\/2026\/01\/PDA-JPST.jpg","datePublished":"2026-02-26T18:22:47+00:00","dateModified":"2026-07-01T22:53:41+00:00","breadcrumb":{"@id":"https:\/\/sterile.com\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sterile.com\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/sterile.com\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/#primaryimage","url":"https:\/\/sterile.com\/wp-content\/uploads\/2026\/01\/PDA-JPST.jpg","contentUrl":"https:\/\/sterile.com\/wp-content\/uploads\/2026\/01\/PDA-JPST.jpg","width":752,"height":265},{"@type":"BreadcrumbList","@id":"https:\/\/sterile.com\/news\/in-situ-verification-of-disinfection-rotation-for-contamination-control\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sterile.com\/"},{"@type":"ListItem","position":2,"name":"In-situ Verification of Disinfection Rotation for Contamination Control"}]},{"@type":"WebSite","@id":"https:\/\/sterile.com\/#website","url":"https:\/\/sterile.com\/","name":"Veltek","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sterile.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"}]}},"_links":{"self":[{"href":"https:\/\/sterile.com\/pt\/wp-json\/wp\/v2\/news\/605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sterile.com\/pt\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/sterile.com\/pt\/wp-json\/wp\/v2\/types\/news"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sterile.com\/pt\/wp-json\/wp\/v2\/media\/28427"}],"wp:attachment":[{"href":"https:\/\/sterile.com\/pt\/wp-json\/wp\/v2\/media?parent=605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}